WM5-96 Instruction Manual
Programming WM5 96
T
his function allows the user to set the Ethernet port. Choose the
ETHERNET PORT function (1) by means of the “ ” keys and con-
firm with “S”.
IP ADDRESS (2): set the IP parameters. Select IP ADDRESS by
means of the “ ” keys and confirm with “S”. Then select IP (IP
a
ddress) or MASK (netmask) by means of the “ ” keys and con-
firm with “S”. Set the value (2a) by means of the “ ” keys, where
t
he “ ” key increases the value and the “ ” key switches to the fol-
lowing number. Confirm with “S”.
GATEWAY (2): set the IP gateway parameters. Select GATEWAY by
means of the “ ” keys and confirm with “S”. Set the value (2b) by
means of the “ ” keys, where the “ ” key increases the value
and the “ ” key switches to the following number. Confirm with “S”.
MODBUS TCP/IP (2): to modify the default port of the Ethernet port
(502), select MODBUS TCP/IP by means of the “ ” keys and con-
firm with “S”. Set the value
(2b), from 1 to 65535, by means of the
” keys and confirm with “S”.
To exit the various menus and submenus, keep the “S” key pressed
for at least 2 seconds.
Thanks to the digital filter, it’s possible to stabilize the measurements
which ar
e too instable when displaying the r
elevant values.
By means of the “ ” keys, select FILTER and confirm with “S”. Select
the function to be set from the various submenus with the “ ” keys
and confirm with “S”:
RANGE (3): set the operating range of the digital filter. The value is
expressed as a %. By means of the “ ” keys select RANGE and
confirm with “S”, then set the value as a percentage by means of the
” keys and confirm the value with the “S” key.
COEFFICIENT (4): set the filtering coefficient of the instantaneous
measures. By increasing the value, also the stability and the settling
time of the measur
es are increased. Select COEFFICIENT by means of
the “ ” keys and confirm with the “S” key, then set the value by
means of the “ ” keys and confirm the new value with the “S” key.
Ethernet Port
Digital filter
*
*
*
*
*
*
*
*
*
*
M
M
A
A
I
I
N
N
M
M
E
E
N
N
U
U
*
*
*
*
*
*
*
*
*
*
R
R
E
E
V
V
.
.
1
1
.
.
4
4
.
.
2
2
.
.
6
6
(
(
A
A
V
V
5
5
)
)
EVENT SELEC.
ANALOG OUTPUTS
SERIAL OUTPUT
FIL
TER
*
*
*
*
*
*
*
*
*
*
M
M
A
A
I
I
N
N
M
M
E
E
N
N
U
U
*
*
*
*
*
*
*
*
*
*
RANGE
COEFFICIENT
1
2
> 2s
> 2s
Measure
Go back
RANGE
1,000%
min
0.100%
max
100.0%
123...
4
COEFFICIENT
4,000%
min
1.100%
max
255.0%
123...
Confir
m
Confirm
3
I
P ADDRESS
G
ATEWAY
*
*
*
*
*
*
*
*
*
*
M
M
A
A
I
I
N
N
M
M
E
E
N
N
U
U
*
*
*
*
*
*
*
*
*
*
R
R
E
E
V
V
.
.
1
1
.
.
4
4
.
.
2
2
.
.
6
6
(
(
A
A
V
V
5
5
)
)
E
VENTS SELEC.
ANALOG OUTPUTS
S
ERIAL OUTPUT
E
THERNET PORT
*
*
*
*
*
*
*
*
E
E
T
T
H
H
E
E
R
R
N
N
E
E
T
T
M
M
E
E
N
N
U
U
*
*
*
*
*
*
*
*
1
2
> 2s
> 2s
Measure
Go back
P
OR
T ?
5020
0.
m
in
100000
m
ax
655350
2a
2
c
123...
I
P
MASK
255. 255. 255. 0
1
92. 168. 2. 122
123...
> 2s
Go back
MODBUS TCP/IP
GW IP
000. 000. 0. 000
123...
> 2s
Go back