ENGLISHModular Panel MeterSeries EDM 35CONTENTS Page1. Introduction 21.1 Getting Started 21.2 Overall Description 31.3 Features 31.4 Block Schematic 4
ENGLISH10If you later want to replace the engineering unit (3), you insert a screw-driver into the lateral slot in the front panel and turn (be carefu
ENGLISH11VoltmetersVDC input module 5100530/630VAC input module 5100531/631Input JumperRange position200 mV2 V20 V200 V600 V3.4.1 Voltmeters4 • • 1
ENGLISH12OhmmetersOhm input module 5100535/635Input JumperRange position200 Ω2 kΩ20 kΩ200 kΩ3.4.3 Ohmmeters4 • • 15 • • 26 • • 34 • • 15 •
ENGLISH13TachometerInput module 5100540/640Range Jumper position199.9 rpm30 ppr199.9 rpm60 ppr199.9 rpm100 ppr1999 rpm30 ppr1999 rpm60 ppr1999 r
ENGLISH144 • • 15 • • 26 • • 3Excitation Power SupplyOutput module 5100526Output JumperVoltage position12 VDC24 VDC4 • • 15 • • 26 • • 34
ENGLISH153.5 Input Range SelectionWhen you have selected the range on the input module (according to3.4 Jumper Setting on Modules) you have to update
ENGLISH164444 OOOOppppeeeerrrraaaattttiiiioooonnnn &&&& PPPPrrrrooooggggrrrraaaammmmmmmmiiiinnnnggggChapter 4 describes t
ENGLISH17The flowchart showshow you get accessto the different modesof operation.4.2.1 Measurement and ControlIn the measuring and control operating
ENGLISH4.2.1.1 Setpoint 1 Value Read-out (SP1)Press and release.After displaying the setpoint value for 2 seconds the instrument will re-tur
ENGLISH19Scaling OperationSetpoint OperationGross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected]
ENGLISH21111 IIIInnnnttttrrrroooodddduuuuccccttttiiiioooonnnn1.1 Getting StartedHow to prepare the EDM 35 for useFor convenience you have a ch
ENGLISH204.2.2 Programming Mode The programming mode allows the user to define the instrument para-meters:- Password for access to programming- Deci
ENGLISH214.3 Programming4.3.1 New Password1. After you have entered the password the display shows .After 2 s the stored value of the passw
ENGLISH222. To select a new value of HiE, press and/or until the desired value is displayed, for example . Press to
ENGLISH232. To select a new Hi value, press and/or until the desired value is displayed. Press to enter the value. 3. After
ENGLISH24S1. The display shows for approx. 2 s. The display then showsthe current value stored in the memory. Accept the value by pressing
ENGLISH252. To select a new relay status, press to select the normally energized status (the display will show ) or press
ENGLISH265555 AAAApppppppplllliiiiccccaaaattttiiiioooonnnn HHHHiiiinnnnttttssss5.1 DC Ammeters with current output transducers5.1.1If the i
ENGLISH275.1.3Connect as indicated if the instrument has to be connected to 2-wiretransducers powered by the instrument.Note:The shown configuration i
ENGLISH286666 OOOOrrrrddddeeeerrrriiiinnnngggg KKKKeeeeyyyyssssAs the EDM is modular, you can assemble a unit of modules withoutusing tools.
ENGLISH296.1 Ordering Key for Modules (continued)Output Modules: Part Number1 Relay 51005612 Relays 5100562Analogue Output 510056012/24 VDC Excitati
ENGLISH31.2 Overall Description The EDM series 35 is based on a modularconcept consisting of a main unit and plug-inmodules. The concept provides the
ENGLISH30B: Range (EDM) (cont.)DC ammeters A1D: -199.9 to 199.9 µAA2D: -1.999 to 1.999 mAA3D: -19.99 to 19.99 mAA4D: -199.9 to 199.9 mAA5D: -1999 to 1
ENGLISH31Ordering Key ExampleEDM 35 V1D 4 1 X XXYCarlo Gavazzi digital meter 3 1/2 digit-199.9 to 199.9 mV DC input230 VAC power supply1 relay output
ENGLISH327777 SSSSppppeeeecccciiiiffffiiiiccccaaaattttiiiioooonnnnssss7.1 Main Unit 7.1.1 General SpecificationsModular Panel Meter 3 1/2 dig
ENGLISH33Housing colours Black (front red, optional green).Module connection Screw terminals.7.1.2 Supply SpecificationsRated operational 230 VAC ± 1
ENGLISH347.2 Module Specifications & Scaling ValuesIn this chapter the specifications and the scaling values (input modulesonly) are described fo
ENGLISH357.2.1 DC Voltmeter (5100530 and 5100630)Code(EDM)V1DV2DV3DV4DV5DRange±199.9 mV±1.999 V±19.99 V±199.9 V±600 V *Resolution0.1 mV1 mV10 mV0.1 V
ENGLISH367.2.3 DC Ammeter (5100532 and 5100632)Code(EDM)A1DA2DA3DA4DA5DA6DRange±199.9 µA±1.999 mA±19.99 mA±199.9 mA±1999 mA±5.00 AResolution0.1 µA1 µ
ENGLISH377.2.5 10 A AC/DC Ammeter (5100534 and 5100634)Code(EDM)A7AA7DRange10 A AC±10 A DCResolution10 mAAccuracy0.5% ± 5 dgt0.5% ± 5 dgtTemperatured
ENGLISH387.2.7 Pt 100 Thermometer (5100536 and 5100636) - continuedCode(EDM)P1CP1FP2FRange-100.0 to 199.9°C-148.0 to 199.9°F-148.0 to 392°FDP111.1 11
ENGLISH397.2.10 Thermocouple Type K Thermometer (5100538 and 5100638)Code(EDM)-KC-KFSensortypeThermocoupleType KRange-100 to 1250°C-148 to 1999°FRe
ENGLISH41.4 Block Schematic2222 UUUUnnnniiiitttt DDDDeeeessssccccrrrriiiippppttttiiiioooonnnn2.1 Modules2.1.1 Common descriptionThe modul
ENGLISH407.2.14 Excitation Output Module (5100526)Outputvoltage12 VDC ± 20%24 VDC ± 20%Max. allowableoutput current35 mA20 mAShort-circuitprotection
ENGLISH417.2.15 Analogue Output Module (5100560)Outputrange0 - 20 mA4 - 20 mA0 - 10 VAccuracy±1% ±0.1 mA±1% ±0.05 VTemperaturedrift±200 ppm/°CLoadres
ENGLISH427.2.16 Relay Output Modules (5100561 and 5100562)Modulenumber51005615100562SPDTcon-tacts12RatedInsulationvoltage250 VBasicAC1load5 A250 VACD
ENGLISH437.3 Mechanical DimensionsBelow are shown the mechanical dimensions of the panel meter, themaximum allowable thickness of the panel and the p
ENGLISH448888 AAAAppppppppeeeennnnddddiiiixxxx8.1 Reset of PasswordThe programming access password is factory set to ‘0’. For returningthe pas
ENGLISH45Enter programming mode: Press and simultaneously.Change parameters: Press and/or . Step to next par
ENGLISH46Commands & PasswordsSetpoint 1 value Press .Setpoint 2 value Press .Peak & Valley values Press and
ENGLISH47NotesGross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected]
ENGLISHNotesGross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected]
ENGLISH52.1.2 Variants2.1.2.1 Power Supply ModulesYou will always need the power supply module. These areavailable for the most common supply volta
ENGLISH62.1.2.3 Output ModulesThe output modules are divided into the following categories:Relay output (1 or 2 relays)Analogue output (4-20 mA, 0-2
2.2 Main Unit2.2.1 DescriptionThe main unit includes a 3 1/2 digit, 7-segment display with alarm indi-cators, a motherboard for 1 power supply modul
ENGLISH82 Display3 1/2 digit (max. read-out 1999). Alphanumeric indication of:- Measured value- Programming parameters3 Alarm IndicatorsIndicates